Friday 3 February 2012

Philipos DPV630 faulty power supply.

A DVD player that would not power up, just a flickering red standby light.

A close inspection revealed  a bulged capacitor. A chance to use the ESR meter in circuit, it confirmed the capacitor was bad.


Component out, definitely gone.


New capacitor in and it was working again.

No comments:

Post a Comment